Installing Signalware Service Pack 5T
Installing Service Pack 5T builds on the example of a default Signalware 9 installation earlier in this chapter.
This patch installation example uses the same user (
siguser) and user group (users) information and assumes that you have performed the base installation and configuration procedures documented earlier in this chapter.Installing the Patch Package
To add Service Pack 5T to a Signalware 9 installation:
- Log in as root.
- If you have not done so already, download and unpack the Signalware 9 Service Pack 5T file (
SIGNALWARE_9_SP5.T_SOLARIS10_UPGRADE.TGZ).- Copy the Signalware Service Pack 5T package file from its location in your download directory or from a Signalware CD to a temporary working directory (
/tmp/omni/5Tis used in the example below).- If Signalware is running, shut it down.
- Start the Signalware installation.
The script prompts for a user identifier.
The Main Menu screen is displayed.
Welcome. This menu gives you options for different Ulticom (R) products. Selecta product to get started.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Signalware Main Menu 04 September 2008 18:151 = Install/Configure (Signalware is uninstalled or off-line)2 = Online Upgrade (Signalware is installed and running)3 = Installation Status and Reports4 = Installation Maintenance5 = Configuration Maintenance6 = Start an Installed Instance of Signalware>Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe Install/Configure screen is displayed.
Welcome. Signalware 9.02 or greater has been installed on your system. All menuoptions are available to you. Select an option to get started. Remember,additional help for each menu is available by typing F12 or entering "help" atthe prompt.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Install/Configure 04 September 2008 18:151 = [ ]Limit Installations to a Single Instance2 = [X]Allow Multiple Installation Instances of Signalware3 = Perform Initial Signalware Installation and Configuration4 = Replace Signalware (replace an existing installation with new GA)5 = Upgrade One of the Currently Installed Installation Instances (SP or ECN)6 = Clone a Currently Installed Instance and Upgrade the Clone>Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe Product Menu screen is displayed.
If you are working on a system with the default configuration, only one installation is listed.The default behavior for installation allows multiple installation instances(Staged Installation). If you wish to restrict this behavior, please selectoption 1. Re-enable staged installation by selecting option 2. To install forthe first time, select option 3. To delete and replace an existing instance,select option 4. To upgrade an instance, select option 5. To clone and upgradean instance, select option 6. More detailed descriptions of these options areavailable from the help menu. Remember, pressing F12 or typing "help" at anymenu will display additional help.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Select Instance to Upgrade 04 September 2008 18:161 = (C) /opt/ulcm>Type 1-1 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe
Upgrade Instancescreen is displayed.Select the instance to upgrade."(C)" indicates the instance is commissioned while "(D)" indicatesit is decommissioned or was never commissioned.Please note, if you select the currently running instance, (i.e. thecommissioned instance), you will be asked to terminate Signalwarebefore installing the packages.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))/opt/ulcm Upgrade Instance 04 September 2008 18:161 = [ ]Install Packages2 = [ ]Configure Platform3 = [ ]Commission Instance4 = [ ]Configure Nodes5 = [ ]Start Signalware6 = Done>Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe
Package Directoryscreen is displayed.This path will perform an offline upgrade of an existing instance. Begin byselecting "Install Packages" to install Signalware in the directory of yourchoice. Remember, entering an option number followed by -manpage or -help willdisplay the manpage for the corresponding command.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))/opt/ulcm Package Directory 04 September 2008 18:16Enter the directory path containing the packages to be installed. This may be alocal or network path or the mount point for a CDROM or DVD-ROM device. If thepackages to install are in more than one directory enter the first directory toinstall. You will be prompted for additional directory paths after each set ofpackages are installed.>/tmp/omni/5TPlease enter directory containing the Signalware software []:
- Enter the path to the patch package file. In the screen above,
/tmp/omni/5Tis shown as the location.The
Upgrade Instancescreen is displayed after the patch is applied.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))/opt/ulcm Upgrade Instance 04 September 2008 18:171 = [X]Install Packages2 = [ ]Configure Platform3 = [ ]Commission Instance4 = [ ]Configure Nodes5 = [ ]Start Signalware6 = Done>Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusAt this point, the patch has been applied. When you restart Signalware, the existing configuration is invoked. Check both the Signalware and Steel-Belted Radius Carrier log entries to ensure that everything is working properly.
The
Install/Configurescreen is displayed.>6 -overrideType 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusYou have completed the Configure Nodes step. Signalware is now ready to run on this CE. To start Signalware, select the "Start Signalware" option. You will need to specify where the Signalware output is to be displayed. The output may be displayed in a new xterm by supplying a display value, to an existing xterm or the console by supplying the device file (ex. /dev/console) or to a file by supplying the file name.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Install/Configure 04 September 2008 18:331 = [ ]Limit Installations to a Single Instance2 = [X]Allow Multiple Installation Instances of Signalware3 = Perform Initial Signalware Installation and Configuration4 = Replace Signalware (replace an existing installation with new GA)5 = Upgrade One of the Currently Installed Installation Instances (SP or ECN)6 = Clone a Currently Installed Instance and Upgrade the Clone>Press Key "F11"Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe
Main Menuscreen is displayed.The default behavior for installation allows multiple installation instances (Staged Installation). If you wish to restrict this behavior, please select option 1. Re-enable staged installation by selecting option 2. To install for the first time, select option 3. To delete and replace an existing instance, select option 4. To upgrade an instance, select option 5. To clone and upgrade an instance, select option 6. More detailed descriptions of these options are available from the help menu. Remember, pressing F12 or typing "help" at anymenu will display additional help.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Signalware Main Menu 04 September 2008 18:341 = Install/Configure (Signalware is uninstalled or off-line)2 = Online Upgrade (Signalware is installed and running)3 = Installation Status and Reports4 = Installation Maintenance5 = Configuration Maintenance6 = Start an Installed Instance of Signalware>Press Key "F11"Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe
Product Menuscreen is displayed.Welcome. Signalware 9.02 or greater has been installed on your system. All menu options are available to you. Select an option to get started. Remember, additional help for each menu is available by typing F12 or entering "help" at the prompt.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Product Menu 04 September 2008 18:341 = Signalware .................... Develop/Deploy SS7 Services2 = nSignia ....................... SS7 and IP Networks Convergence3 = Client/Server Client .......... Client/Server Client Components4 = WLAN Libraries ................ Authentication/SMS Library Source5 = Diameter ...................... Network Access or IP Mobility Protocol6 = Lower Layer Board (LLB) API ... ATM API for AMC board7 = Exit>7Type 1-7 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=StatusThe
Product Menuscreen is displayed.Welcome. This menu gives you options for different Ulticom (R) products. Select a product to get started.HOST: mercury Ulticom (R) Product Menu sigusr (uid=0(root) gid=0(root))Product Menu 04 September 2008 18:34You are about to exit the Signalware Menu System. Are you sure you want to exit? To continue using the menu system enter Y. To exit enter N.>A confirmation prompt is displayed.
Would you like to continue the Signalware Menu System? (Y/N)[Y]: