[Contents] [Prev] [Next] [Index] [Report an Error] [No Frames]


Installing Signalware Service Pack 5T

Installing Service Pack 5T builds on the example of a default Signalware 9 installation earlier in this chapter.

This patch installation example uses the same user (siguser) and user group (users) information and assumes that you have performed the base installation and configuration procedures documented earlier in this chapter.

Installing the Patch Package

To add Service Pack 5T to a Signalware 9 installation:

  1. Log in as root.
  2. If you have not done so already, download and unpack the Signalware 9 Service Pack 5T file (SIGNALWARE_9_SP5.T_SOLARIS10_UPGRADE.TGZ).
  3. Copy the Signalware Service Pack 5T package file from its location in your download directory or from a Signalware CD to a temporary working directory (/tmp/omni/5T is used in the example below).
  4. If Signalware is running, shut it down.
  5. Start the Signalware installation.

Execute:
swsetup

The script prompts for a user identifier.

  1. Enter the unique user that you created in the initial installation: siguser.

The Main Menu screen is displayed.

Welcome. This menu gives you options for different Ulticom (R) products. Select
a product to get started.

HOST: mercury                 Ulticom (R) Product Menu                    sigusr (uid=0(root) 
gid=0(root))
                                Signalware Main Menu                               04 September 2008 
18:15

 1 = Install/Configure (Signalware is uninstalled or off-line) 
 2 = Online Upgrade (Signalware is installed and running) 
 3 = Installation Status and Reports 
 4 = Installation Maintenance 
 5 = Configuration Maintenance 
 6 = Start an Installed Instance of Signalware 




>
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                      
  1. Enter 1 to install the patch.

The Install/Configure screen is displayed.

Welcome. Signalware 9.02 or greater has been installed on your system. All menu
options are available to you. Select an option to get started. Remember,
additional help for each menu is available by typing F12 or entering "help" at
the prompt.

HOST: mercury                 Ulticom (R) Product Menu                    sigusr (uid=0(root) 
gid=0(root))
                                 Install/Configure                                 04 September 2008 
18:15

 1 = [ ]Limit Installations to a Single Instance 
 2 = [X]Allow Multiple Installation Instances of Signalware 
 3 = Perform Initial Signalware Installation and Configuration 
 4 = Replace Signalware (replace an existing installation with new GA) 
 5 = Upgrade One of the Currently Installed Installation Instances (SP or ECN) 
 6 = Clone a Currently Installed Instance and Upgrade the Clone 




>
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                      
  1. Enter 5 to select the Signalware installation that requires the patch.

The Product Menu screen is displayed.
If you are working on a system with the default configuration, only one installation is listed.

The default behavior for installation allows multiple installation instances
(Staged Installation). If you wish to restrict this behavior, please select
option 1. Re-enable staged installation by selecting option 2. To install for
the first time, select option 3. To delete and replace an existing instance,
select option 4. To upgrade an instance, select option 5. To clone and upgrade
an instance, select option 6. More detailed descriptions of these options are
available from the help menu. Remember, pressing F12 or typing "help" at any
menu will display additional help.

HOST: mercury                 Ulticom (R) Product Menu

sigusr (uid=0(root) gid=0(root))
Select Instance to Upgrade                             04 September 2008 18:16

 1 = (C) /opt/ulcm 


>
Type 1-1 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                      
  1. Enter 1 to select the location of the Signalware 9 installation.

The Upgrade Instance screen is displayed.

Select the instance to upgrade.
"(C)" indicates the instance is commissioned while "(D)" indicates
it is decommissioned or was never commissioned.
Please note, if you select the currently running instance, (i.e. the
commissioned instance), you will be asked to terminate Signalware
before installing the packages.

HOST: mercury                 Ulticom (R) Product Menu                    sigusr (uid=0(root) 
gid=0(root))
/opt/ulcm                         Upgrade Instance                                 04 September 2008 
18:16

 1 = [ ]Install Packages 
 2 = [ ]Configure Platform 
 3 = [ ]Commission Instance 
 4 = [ ]Configure Nodes 
 5 = [ ]Start Signalware 
 6 = Done 


>
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status

  1. Enter 1 to install the package.

The Package Directory screen is displayed.

This path will perform an offline upgrade of an existing instance. Begin by
selecting "Install Packages" to install Signalware in the directory of your
choice. Remember, entering an option number followed by -manpage or -help will
display the manpage for the corresponding command.

HOST: mercury                 Ulticom (R) Product Menu                    sigusr (uid=0(root) 
gid=0(root))
/opt/ulcm                        Package Directory                                 04 September 2008 
18:16

Enter the directory path containing the packages to be installed. This may be a
local or network path or the mount point for a CDROM or DVD-ROM device. If the
packages to install are in more than one directory enter the first directory to
install. You will be prompted for additional directory paths after each set of
packages are installed.





>/tmp/omni/5T
Please enter directory containing the Signalware software []:

  1. Enter the path to the patch package file. In the screen above, /tmp/omni/5T is shown as the location.

The Upgrade Instance screen is displayed after the patch is applied.


HOST: mercury           Ulticom (R) Product Menu                    sigusr (uid=0(root) gid=0(root))
/opt/ulcm                         Upgrade Instance                                 04 September 2008 
18:17

 1 = [X]Install Packages 
 2 = [ ]Configure Platform 
 3 = [ ]Commission Instance 
 4 = [ ]Configure Nodes 
 5 = [ ]Start Signalware 
 6 = Done 




>
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                      

At this point, the patch has been applied. When you restart Signalware, the existing configuration is invoked. Check both the Signalware and Steel-Belted Radius Carrier log entries to ensure that everything is working properly.

  1. Enter 6 -override (this is not a choice on the menu) to exit.

The Install/Configure screen is displayed.

>6 -override
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                                                                

You have completed the Configure Nodes step. Signalware is now ready to run on this CE. To start 
Signalware, select the "Start Signalware" option. You will need to specify where the Signalware output 
is to be displayed. The output may be displayed in a new xterm by supplying a display value, to an 
existing xterm or the console by supplying the device file (ex. /dev/console) or to a file by supplying 
the file name.

HOST: mercury           Ulticom (R) Product Menu                    sigusr (uid=0(root) gid=0(root))
                                   Install/Configure                         04 September 2008 18:33

 1 = [ ]Limit Installations to a Single Instance
 2 = [X]Allow Multiple Installation Instances of Signalware
 3 = Perform Initial Signalware Installation and Configuration
 4 = Replace Signalware (replace an existing installation with new GA)
 5 = Upgrade One of the Currently Installed Installation Instances (SP or ECN)
 6 = Clone a Currently Installed Instance and Upgrade the Clone 




>Press Key "F11"
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                                                                
  1. Press F11.

The Main Menu screen is displayed.


The default behavior for installation allows multiple installation instances (Staged Installation). If 
you wish to restrict this behavior, please select option 1. Re-enable staged installation by selecting 
option 2. To install for the first time, select option 3. To delete and replace an existing instance, 
select option 4. To upgrade an instance, select option 5. To clone and upgrade an instance, select 
option 6. More detailed descriptions of these options are available from the help menu. Remember, 
pressing F12 or typing "help" at any
menu will display additional help.                                                                                
 
HOST: mercury                        Ulticom (R) Product Menu          sigusr (uid=0(root) gid=0(root))
                                     Signalware Main Menu                       04 September 2008 18:34

 1 = Install/Configure (Signalware is uninstalled or off-line)
 2 = Online Upgrade (Signalware is installed and running)
 3 = Installation Status and Reports
 4 = Installation Maintenance
 5 = Configuration Maintenance
 6 = Start an Installed Instance of Signalware 




>Press Key "F11"
Type 1-6 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                                                                
  1. Press F11.

The Product Menu screen is displayed.


Welcome. Signalware 9.02 or greater has been installed on your system. All menu options are available 
to you. Select an option to get started. Remember, additional help for each menu is available by typing 
F12 or entering "help" at the prompt.

HOST: mercury              Ulticom (R) Product Menu                    sigusr (uid=0(root) gid=0(root))
                           Product Menu                                         04 September 2008 18:34

 1 = Signalware .................... Develop/Deploy SS7 Services
 2 = nSignia ....................... SS7 and IP Networks Convergence
 3 = Client/Server Client .......... Client/Server Client Components
 4 = WLAN Libraries ................ Authentication/SMS Library Source
 5 = Diameter ...................... Network Access or IP Mobility Protocol
 6 = Lower Layer Board (LLB) API ... ATM API for AMC board
 7 = Exit 



>7
Type 1-7 <enter>; <esc> or F11=Previous Menu; F12=Help; ?<enter>=Status
                                                                                
  1. Enter 7.

The Product Menu screen is displayed.


Welcome. This menu gives you options for different Ulticom (R) products. Select a product to get 
started.

HOST: mercury              Ulticom (R) Product Menu                    sigusr (uid=0(root) gid=0(root))
                           Product Menu                                         04 September 2008 18:34

You are about to exit the Signalware Menu System. Are you sure you want to exit?  To continue using the 
menu system enter Y.  To exit enter N.








>
  1. Enter N.

A confirmation prompt is displayed.


Would you like to continue the Signalware Menu System? (Y/N)[Y]:

  1. Press Enter to exit.


[Contents] [Prev] [Next] [Index] [Report an Error] [No Frames]